Use this chart to troubleshoot common problems with the HDL-32E.
P
r
o
b
l
e
m
R
e
s
o
l
u
t
i
o
n
Unit doesn’t spin
Verify power connection and polarity.
Verify proper voltage
should be between 9 and 32 volts
drawing a minimum of one amp.
Inspect the fuse in the interface module.
Replace if necessary.
Unit spins but no data
Verify Ethernet wiring.
Verify packet output using another application
(e.g. EthereallWireshark).
Verify network settings.
Set a static IP address in network settings. 192.168.3.255.
Verify that no security software has been installed which may block
Ethernet broadcasts.
.
S E R V I C E A N D M A I N T E N A N C E
There are no user service or maintenance requirements or procedures for the Velodyne HDL-32E.
For service or maintenance, please contact Velodyne at +1 (408) 465-2800, or log on to our website at www.velodynelidar.com.