Appendix J: Troubleshoot
Use the chart below to troubleshoot common problems with the sensor.
Problem
Resolution
Unit doesn’t spin
Verify power connection and polarity.
Verify proper voltage
should be 24 volts drawing about 3.5 to 4
amps.
Unit spins but no data
Verify Ethernet wiring.
Verify packet output with another tool (e.g. Ethereal/Wireshark).
No serial communication
Verify RS-232 connection.
Unit must be active and spinning for RS-232 update.
It may take several tries for the update to be effective.